How to Use the Aerobika* Oscillating Positive Expiratory Pressure Therapy System
How to Use the Aerobika* Oscillating Positive Expiratory Pressure Therapy System
This video demonstrates how to use the AEROBIKA* Oscillating Postitive Expiratory Pressure Therapy System. Learn more here: http://www.trudellmed.com/consumer-he…
Content
1.369 -> Please follow these simple
instructions when using Aerobika*
5.879 -> Oscillating Positive Expiratory
Pressure therapy system
9.269 -> or Oscillating PEP device. The proper
resistance setting
14.509 -> is key to effective PEP treatments. Your
health care professional will determine
19.64 -> what
20.02 -> resistance setting is right for you.
Always ensure the resistance
24.279 -> indicator is set as prescribed by your
healthcare professional.
28.279 -> The Aerobika* Oscillating PEP device
can be used
32.989 -> right out of the package. Before use
ensure you have read the instructions
37.61 -> for use
38.2 -> included with your device. First
41.52 -> look at the device and make sure it is
not damaged.
44.62 -> if it is damaged replace it immediately.
47.68 -> Put the mouthpiece in your mouth closing
your lips around it
52.31 -> forming a good seal. Make sure your hand
does not block the exhalation path on
57.32 -> the back of the device.
58.69 -> With your lips still sealed around the
mouthpiece
62.78 -> inhale deeply then hold your breath for
2 to 3 seconds
67.04 -> before exhaling actively but not
forcefully through the device.
71.43 -> Active exhalation should last 3 to
4 times longer than
76.86 -> inhalation. Keep your cheeks flat and
firm
80.4 -> for the most effective treatment.
Continue taking
84.6 -> deep breaths and long exhalations for
10 to 20 breaths
88.979 -> or as instructed by your healthcare
professional
92.28 -> after which you will perform 2 to 3
95.5 -> huff coughs to clear your airways. Your
health care professional will instruct
101.14 -> you on the proper
102.44 -> huff cough technique.
105.87 -> Continue this cycle for 10 to 20
minutes or again
109.82 -> as prescribed by your healthcare
professional. Treatment should be
114.47 -> performed twice
115.66 -> each day and increased to 3 to 4
times per day
119.31 -> if you're coughing produces a lot of
mucus.
124.04 -> If you feel dizzy or lightheaded or if
you have any discomfort
128.35 -> stop your treatment and contact your
health care provider.
131.69 -> Your Aerobika* Oscillating PEP therapy system
137.33 -> can also be combined with your nebulizer treatment.
140.37 -> We recommend the use of the AeroEclipse* XL Breath Actuated Nebulizer
145.47 -> and Ombra* Compressors. Ensure you have read the instructions provided with your
150.93 -> nebulizer
151.709 -> before starting your treatment. Set up
your nebulizer
155.72 -> and ensure your prescribed medication
has been added to the nebulizer cup.
160.23 -> Ensure the nebulizer is set to breath
163.32 -> actuated mode. Remove the mouthpiece
from the nebulizer
168.12 -> and attach it to the nebulizer port on the Aerobika* Oscillating PEP device.
173.04 -> Switch on the compressed air source
175.98 -> and complete your combined treatment using the breathing technique
179.07 -> from the previous section.
183.099 -> The Aerobika* Oscillating PEP device
disassembles
186.2 -> in to four parts for cleaning. To
disassemble
189.65 -> press the tabs on either side of the
device and gently pull the top and
194.239 -> bottom case apart.
195.59 -> Then remove the valve cartridge and
mouthpiece.
198.59 -> Do not disassemble any part of the valve
cartridge.
202.209 -> Wash the four parts in warm soapy water
207.17 -> allowing the parts to soak for 15
minutes.
210.349 -> Agitate gently. Rinse in warm
distilled water
214.75 -> and shake out any excess water. Allow
parts to air dry thoroughly
220.67 -> before you reassemble the device.
228.15 -> The device is also dishwasher safe.
231.14 -> Secure the device in a basket on the top
rack
234.59 -> and run through a light or normal cycle.
Shake out
238.07 -> any excess water and always allow the
device to air dry thoroughly
242.48 -> before reassembly. To reassemble the
device
246.56 -> slip the valve cartridge in to the bottom
case.
250 -> If it does not fit rotate the cartridge
and try again.
253.63 -> Re-attach the top and bottom cases until
you hear the tabs click
258.34 -> in to place. Ensure they are securely
engaged by firmly pressing
263.09 -> the two halves together. Re-attach the
mouthpiece.
267.14 -> The Aerobika* Oscillating
270.99 -> PEP device should be disinfected once
each treatment day
274.54 -> using any of these methods.
286.009 -> If you have any questions
287.789 -> please ask your health care provider